Dual Force Control |
|
Home
/ Control systems / Dual Force Control
|
When using Displacement for Tablet Weight Control, the final compression station is only used to give the tablet its final Hardness and hence Thickness. The Dual Control option adds a second control loop for constant tablet hardness at the final compression. After the press has been set-up for automated weight control and the operator has verified the tablet hardness, the second control loop will keep the final compression force constant. Force variations will be adjusted by repositioning the compression rollers within pre-set product limits.
|
Request Information
If you are interested in learning more about a particular product and/or service offered by GEA Process Engineering Inc, please use this form to contact us,
GEA Courtoy Business Unit
GEA Process Engineering Inc. Email: Michael Fazio |
||
|
|